Atwood Hydro Flame Furnace User Manual

Download 79 Atwood Furnace PDF manuals. User manuals, Atwood Furnace Operating guides and Service manuals. Download 79 Atwood Furnace PDF manuals. User manuals, Atwood Furnace Operating guides and Service manuals.

Advertising

1

THIS INSTRUCTION MANUAL IS FOR USE BY AN AUTHORIZED SERVICE
TECHNICIAN TO INSTALL AN ATWOOD

- hydro flame

TM

FURNACE

.

INSTALLER

:

LEAVE THIS MANUAL WITH APPLIANCE

.

CONSUMER

:

RETAIN THESE MANUAL FOR FURTHER
REFERENCE

.

This furnace design has been certified for installation in recre-
ation vehicles as a MSP Category III furnace. Follow this installa-
tion instruction to insure safe operation of the furnace. Failure to
install furnace according to this installation instruction nullifies
the furnace warranty.

SAFETY ALERT SYMBOLS

Safety Symbols alerting you to potential personal safety hazards.
Obey all safety messages following these symbols.

ƽ

WARNING

ƽ

CAUTION

avoid possible

avoid possible

injury or death

injury and/or property damage

INDEX

FURNACE SPECIFICATIONS

..............................................................1

DIMENSIONS

..................................................................1

WEIGHT

........................................................................1

MINIMUM CLEARANCE TO FLOORBOARDS

,

WALLS

,

&

SIMILAR COMBUSTIBLE BUILDING MATERIALS

..................................

2

SAFETY INFORMATION

..................................................................

1-2

FURNACE INSTALLATION

..................................................................

2

VENT INSTALLATION - HORIZONTAL & VERTICAL

......................................

2

WALL CUTOUT

HORIZONTAL & VERTICAL

..............................................

2

-

3

DUCTING

HORIZONTAL & VERTICAL

......................................................

3

Flexible Ducting

......................................................................

3

Hard Ducting

........................................................................

3

OPTIONAL INSTALLATION

-

BOTTOM DISCHARGE KIT

..................................

3

GAS CONNECTION

........................................................................

3

ELECTRICAL CONNECTIONS

..........................................................

3-4

Conductor Sizing Table

............................................................

3

12 volt DC Models

..................................................................

3

120 volt AC Models

..............................................................

Atwood hydro flame furnace user manual free

3

-

4

Thermostat

..........................................................................

4

CONVERTIBLE GAS CONTROL

Hydro

............................................................

4

Valve Conversion

....................................................................

4

Orifice Replacement

................................................................

4

SYSTEM CHECK TESTS

....................................................................

4

PROPANE GAS PRESSURE

..............................................................

4

STATIC PRESSURE

........................................................................

5

AC

&

DC WIRING DIAGRAMS

............................................................

5

ILLUSTRATIONS

............................................................................

6

REPLACEMENT PARTS LIST

&

DRAWING

..............................................

7

SPECIFICATIONS

*

(W.C. = Water Column)

MODEL

#

8935

8940

8935

8940

DCLP

-

III

DCLP

-

III

ACLC

-

III

ACLC

-

III

BTU Input

35,000

40,000

35,000

40,000

Output BTU/HR

27,300

31,200

27,300

31,200

Type Gas

LP

LP

LP/NAT

LP/NAT

Duct Static Pressure -

.10˝ W.C.*

.10˝ W.C.*

.10˝ W.C.*

.10˝ W.C.*

Power Supply (

VOLTS

)

12-DC

12-DC

120-AC

120-AC

Watts -

WITH OUT DOOR

151

151

360

360

Amperage

12.6

12.6

3

3

MINIMUM RETURN AIR

80 in

2

80 in

2

80 in

2

80 in

2

DIMENSIONS

Atwood Hydro Flame Furnace User Manual Pdf

WEIGHT

ALL MODELS WITH DOOR

WIDTH

HEIGHT

DEPTH

Casing

16-1/2˝

9-1/8˝

23-1/2˝ - 26˝

FURNACE

38 lbs.

Vent

5-3/8˝

SHIPPING

45 lbs.

ENGLISH, FRANCAIS

(et Canada)

•Installation

Effective 3/08

LITERATURE NUMBER

MPD 31232

hydro flame

TM

8900-III-LD Series Furnace

MODELS

Hydro

8935, 8940

Technical Installation Manual

WARNING: If the information in this manual is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of
life.

Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.

WHAT TO DO IF YOU SMELL GAS

• Evacuate all persons from vehicle.
• Shut off gas supply at gas container or source.
• Do not touch any electrical switch, or use any

phone or radio in vehicle.

• Do not start vehicle’s engine or electric generator.
• Contact nearest gas supplier or qualified Service

Technician for repairs.

• If you cannot reach a gas supplier or qualified

Service Technician, contact the nearest fire
department.

• Do not turn on gas supply until gas leak(s) has

been repaired.

Installation and service must be performed by a
qualified Service Technician, Service Center or
gas supplier.

Advertising
This manual is related to the following products:
Table of contents
Popular Brands
Popular manuals

Description

Atwood 7920-II

*NEITHER OF THESE KITS ARE APPLICABLE TO A 7920, ONLY TO A 7920-II*

Tune-Up Kit #1 Obsolete / No Longer Available:

Hydro Flame Furnace Troubleshooting Manual

Single Sense Electrode 37517 (One Wire Goes To Electrode)

Atwood Hydro Flame Rv Furnace

Tune-Up Kit #2 Includes:

Dual Sense Electrode 36998 (Two Wires Go To Electrode, When Substituting For Electrode 37517 Only One Gets Connected)

ADDITIONAL ATWOOD FURNACE 7920-II AVAILABLE PARTS LINKS
Item# 1 5 Amp Circuit Breaker 30320
Item# 2 Burner Air Tube 35892
Item# 6 Door Latch 37912
Item# 7 Duct Cover, 4 Inch, 31361
Item# 8 Duct Adapter, 4 Inch, 31474
Item# 9 Duct Adapter, 2 Inch, 36688
Item# 20 Burner Plate Gasket 35890
Item# 24 Motor Mount Assembly 35879 NLA
Item# 27 OEM Ignition Module 31501
Item#27 After-Market Ignition Module 31501MC
*Not Shown* Wiring Harness Kit 30230
Item# 28 Ignition Module Mounting Bracket 37951
Item# 29 Manifold 37391
Item# 30 OEM Motor 31036
Item# 30 After-Market 31036MC
Item# 41 Thermostat, Heat Only, Brown, 38452 NLA
Item# 41 Thermostat, Heat Only, White, 38453
Item# 42 Gas Valve 31150
Item# 45 Vent Kit, 4 Inch, 35955
Item# 45 Vent Kit, 8 Inch, 35956
Item# 45 Vent Kit, 12 Inch, 35957 NLA
Item# 48 Blower Wheel & Clamp Kit 33286
Item# 51 Coil (Replacement for Item# 42 Gas Valve) 31000 NLA
*Not Shown* 2 Inch Heater Duct Hose